Diesel Electric Services has achieved the status of the “Highest Turnover of MGE three phase UPS for a value-adding Re-Seller for 2008.
|
Diesel Electric Services has been strategically partnered with APC by Schneider (formerly APC and MGE) for 4 years as a Gold Partner. This enables us to offer an extensive range of well proven products at the best possible value to you and your customer. |
Galaxy 3000
- Four power ratings: 10 - 15 - 20 - 30 kVA
- Three-phase input and output
- Parallel connection of up to four UPS units, i.e. up to 120 kVA
- On-line double conversion (VFI)
- Automatic and manual bypasses
- PFC system. Clean input current, with a sinusoidal waveform in phase with the voltage, thus eliminating harmonic disturbances (THDI < 3%)
- A high power factor (FP > 0.99)
- Total compatibility with engine generator sets
- A reduction in installation electrical consumption of up to 20%
|  |
Galaxy 5000
- 40 - 60 - 80 - 100 - 120 kVA
- 3-phase input (without neutral) and output
- Parallel connection of up to 6 UPS units
- On-line double conversion (VFI) providing voltage regeneration and isolation from the distribution system
- Automatic and manual bypasses
- 94% efficient at full load 92% efficient at 50% load
- PFC rectifier with sixpack IGBT modules to avoid upstream distortion (upstream THDI < 3%) and with a PF close to 1
- Sixpack IGBT modules designed to reduce the number of connections for greater reliability, compactness and easy access from the front
- Wide input-voltage range from 250 to 470 V to handle disturbed distribution systems
- High overload and discrimination capacity
- Input-current limiting during genset start
- Multilingual, graphic display, high resolution quarter VGA
- Digital batter monitoring by Digibat (calculation of real backup time and remaining battery life) and block by block monitoring (optional)
- Monitoring and communication possibilities via networks and the web with preventive maintenance (Life Cycle monitoring)
|  |
|
Galaxy PW
- 2 power ratings: 160 - 200 kVA
- Three-phase input and output
- Parallel connection of up to four UPS units, i.e. up to 800 kVA
- On-line double conversion (VFI)
- Static switch and manual bypass
- Up to 95% efficient with filter
|  |
|
Galaxy 7000
- 4 power ratings: 250 - 300 - 400 - 500 kVA
- Three-phase input (without N) and output (with N)
- On-line double conversion (VFI)
- Automatic and manual bypasses
- Wide input-voltage range from 250 V (30% load) to 470 V (100% load) to handle disturbed distribution systems
- Input-current limiting during genset start (soft start)
- IGBT-based, PFC sinusoidal-current input rectifier: THDI < 5% and PF > 0.99 starting at 50% load
- Phase-sequence check to ensure power availability
- Separate charger so battery voltage does not depend on the AC source
- Output PF = 0.9
- Output voltage adjustable ± 3% to take into account voltage drops in the cables
-
- High short-circuit capacity for good discrimination up to 3 In
- Efficiency of 94.5% in normal mode,97% in ECO mode
- Power rating increased by 7.5% for ambient temperatures below 20°C
- Power components have independent, redundant ventilation with fault detection
- Multi-standard communication cards with Jbus/Modbus and Ethernet 10/100 Mbps + https pages for Web supervision, NMS
- HMI with graphical interface, 19 languages, measurements, alarms,statistics, 2500 time-stamped events
- Parallel connection of up to 8 UPS units i.e. 8 x 500 kVA = 4 MVA
- Wide choice of architectures, modular UPSs in parallel, parallel UPSs with SSC, with STS, compliant with ANSI/NEMA 942 TIER
|  |
|
SineWave Filter
- The solution for harmonic disturbances of medium-power infrastructure, commercial and industrial applications
- SineWave active harmonic conditioners eliminate upstream of their point of installation the current harmonics caused by the downstream non-linear loads. Digital design means the type of elimination may be selected:
- Overall elimination of all harmonic orders from H2 to H25
- Selective elimination for specific orders
- They are also the means to limit the upstream voltage total harmonic distortion THDU to a selected value (generally 5 to 8%), depending on what is acceptable for sensitive equipment or for the public distribution systems
- SineWave can be used in all types of distribution systems confronted with harmonics, in view of:
- Solving problems in existing installations
- Preventing problems in new installations
Click here to download more information on the Principles of the Active Filter |  |
|
Static Transfer Switch
- 7 ratings: 30 - 60 - 100 - 160 - 250 - 400 - 600 - 800 - 1200 - 1600 A
- Power ratings from 20 to 1100 kVA (at 400 V)
- 3 or 4 poles
- Automatic or manual transfer between sources
- Maintenance bypass on each incomer
- Static transfer technology
- Break-before-make transfer with controlled SCRs
Click here to download more information on how this works |  |
|
|